The DIGIWAY system benefits from an easy-to-use auto-calibration feature.
To successfully complete the auto-calibration, you will need to:
- Set the spring pre-load tension (learn more) - For DIGIWAY SR / DWSR102U only
- Set the door limits (learn more)
- Initiate the auto-calibration (learn more).
To complete the auto-calibration all in one go, follow these steps:
- Open the DIGIWAY app and find the right operator that you want to programme.
- Hold down OK to open the programming menu.
- From the menu, select Door Calibration and then Spring Pre-load.
- Switch the door to Free Mode using the slider in the bottom-left of the app screen.
- Then, increase the spring tension to at least 90.
- Check if the pins on the operator are lined up with the arm.
- Fix the arm to the DIGIWAY operator and pull the door open to check that you have enough tension to close it.
- Press OK to return to the menu.
2. SETTING DOOR LIMITS
- From the menu, select Door Limits.
- Open the door, and when at its open limit, press OK.
- Close the door, and when fully closed, press OK again.
- Press OK to return to the menu.
3. INITIATING AUTO-CALIBRATION
- From the menu, select Auto-Calibration.
- Press OK to confirm and proceed with calibration.
- The door will automatically open and close fully five times while calibrating.
- Once complete, exit the menu and change the door back to Auto Mode using the slider.
You can test the calibrated DIGIWAY by triggering an open command using the Open/Close button on the app screen.