How do I delete a transmitter from an XPL receiver?
How do I delete a transmitter from an XPL receiver?
To delete a transmitter from the memory of a CDVI XPL receiver, simply follow these steps:
Press and hold the P1 buttonto enter the menu.
Scroll down using P2 until you reach Delete.
Then press P1 to confirm your selection.
In the Delete menu, select Delete Tx by pressing P1. The receiver then waits for the transmitter button to be pressed.
Press the button on the transmitter you want to delete from the memory.
To confirm the deletion, use P2 to scroll and select Yes, then press P1 to confirm.
The transmitter has now been deleted from the memory.
Press P2 to scroll through the Delete menu to the Exit option, and press P1 to confirm.
Then scroll again using P2 through the main menu to the Exit option, and press P1 to fully exit the menu.
You can check that the transmitter has been successfully deleted by pressing the button on the transmitter. If you see the message >>>RF<<< you can be sure that the receiver has failed to recognise the transmitter.
Do you need to learn how to add a transmitter to the receiver memory?
To add a transmitter to the memory of a CDVI XPL receiver, follow these simple steps: To add a transmitter, press and hold the P1 button to enter the menu. Once you have entered the menu, release P1 and then press it again to enter the memory. Press ...
To erase all the transmitters memorised on a Z Series receiver, follow these steps: Press P1 until the red LED on DL1 shows. Then release P1, and press again and hold until both the red and green LEDs flash three times. The unit is then fully ...
Introduction Access levels determine which areas in the building a user will have access to and during which schedules. This is done by enabling the access level and then assigning a schedule to each area. In order to define access levels, you must ...
Access levels groups determine which access levels a user with Operator rights will have access to create users and cards. This is done by creating a group of access levels. In order to define access level groups, you must first create Access Levels ...
Using our isync software, ievo fingerprint readers can be used with any access control system that accepts Wiegand connections. For more information about isync, please contact our Technical Support team.