What power does the DIGIWAY Plus require?

The DIGIWAY Plus door operator is mains powered: 240Vac - 5A. 
    • Related Articles

    • DIGIWAY Plus normal operation troubleshooting

      The door isn't operating when triggered Check the door's operation by using the direct open command. Make sure you exit the menu then use the bottom button to immediately trigger an open command. Alternatively, use the radio fob (once it has been ...
    • Does the DIGIWAY Plus hold the door locked?

      No. The DIGIWAY Plus door operator does not hold the door locked. An electronic lock is incorporated for this purpose.
    • Can the DIGIWAY Plus work in wind-affected areas?

      As the DIGIWAY Plus is power-open and power-close, installation in windy or draughty areas will need to be carefully considered. The unit would need to be set up with strong forces to overcome any wind effect. In addition, the obstacle detection ...
    • Can the DIGIWAY Plus be connected to a fire alarm?

      Yes. Terminals 3-4 require 24Vdc, and when this is dropped by the fire alarm system the DIGIWAY Plus will go into Fire Mode (if set up in the settings). Consult the DIGIWAY Plus installation manual for more information about connecting to fire ...
    • Can the DIGIWAY Plus be used manually?

      No. The DIGIWAY Plus is a fully automatic door operator for swing doors. This means it powers open and powers closed. The door should not be used manually. If the door is required to be used manually, then the DIGIWAY Spring Return door operator ...